Proterm instructions for use. Proterm gas boilers are reliable heating equipment. Video: Connecting the Proterm boiler

9

Starting the boiler

Warning: Putting the boiler into
operation and its first start-up must
be produced only by certified

by Protherm specialist
specialized organization!

When starting the boiler for the first time, make sure
is that:

1. the boiler is connected to electrical network And

in this case, the phase and zero are not mixed up.

2. gas shut-off valve is open;
3. service taps for heating and hot water supply

4. The pressure in the heating system is

V permissible limits 1 – 2 bars.
Install the main switch (Fig. 1,
pos. 7) to the ON position (I). Boiler
turns on and starts working in mode
heating water in the boiler (if the boiler
connected to the boiler). After heating the water in
boiler the boiler will switch to mode
heating (provided that the mode
heating active). In case of protective

boiler shutdown on the panel display
control, a message will appear indicating
malfunction (see “Messages about
errors“, page 8). Using a button
RESET (Fig. 1, item 6) unlock
boiler. If, after switching on, the protective
shutdown will occur again or is not possible
will unlock the boiler,
contact your service organization.

Boiler shutdown

In case of a short-term boiler shutdown
install the main switch (Fig.
1, pos. 7) to the OFF position (O).
When the boiler is turned off for a long time
period it is necessary to disconnect it from
electrical network and shut off the supply
gas to the boiler. If in winter period boiler
not used, then the heating system
needs to be emptied. However
Frequent draining must be avoided and
top-up of the heating system to avoid
formation of scale and deposits inside
boiler

Starting and shutting down the boiler

Boiler adjustment

Operating a boiler without room
regulator


according to the readings of the boiler sensor. IN
terminal block XT5 on terminals 5 and 6 is
jumper (factory setting). Order
settings:

Turn on the boiler with the main switch;
set the required temperature

flow line on the control panel.

Operating a boiler with room temperature
thermostat

In this mode, the boiler supports
set temperature in the heating system
by room regulator. Jumper,
installed in the XT5 terminal block on clamps
5 and 6, removed. In its place is connected
room regulator. If indoors
With room regulator on radiators
thermostatic valves installed,
it is necessary to convert them completely
open position.
Warning: On the control panel

Meaning

Malfunction on-
outdoor sensor
temperature

The boiler operates without restrictions, but the temperature

The coolant is regulated by the boiler sensor (see.
“Setting the heating temperature”, page 5).

If the boiler does not operate in equithermal mode, then
such a message cannot appear.

When purchasing any heating equipment, the user receives instructions. It describes all the points that relate not only to the installation of the unit, but also to its operation. The Proterm Skat 9 kW boiler is no exception. Of course, for some reason the instructions were lost, then it will not be possible to start heating the house. After all, an electric boiler needs to be configured correctly. There are certain rules for the installation and operation of an electrical unit. They must be respected. Otherwise, the equipment will not work correctly.

The advantage of the electric boiler Proter Skat

The Proterm Skat unit has a number of advantages. This heating equipment has become a good alternative to gas heating appliances. The popularity of Proterm Skat boilers is increasing every year. After all, such units are ideal for heating houses that are not connected to the main gas pipeline. Electric boilers of this modification are simply irreplaceable for country cottages with periodic or seasonal accommodation.

Among the advantages of such units, the following should be highlighted:

It is worth noting that electric boilers Over the course of its existence, Proterm Skat has proven itself to be an economical and safe heating device.

Installation Features

Proterm Skat 9 kW boilers are supplied with all necessary fasteners and elements. Besides The kit includes instructions that describe the process of connecting and setting up the unit step by step. It is worth noting that models that differ in power have exactly the same principles of installation, operation, and configuration.

Before installing Proterm Skat heating equipment, it is necessary to coordinate all work with electrical distribution services.

Proterm Skat electric boilers with a power of 9 kW can be connected to a conventional 220V electrical network. Installation of such heating equipment is carried out using a mounting strip. Such a unit has no certain restrictions on the choice of installation location. Of course, there are some requirements - you need free access for service, maintenance, adjustment and repair of heating equipment.

How to install

The Proterm Skat electric boiler is connected to the pipe system using pipes. The heating device is connected in such a way that the coolant can be easily drained in case of failures during operation without affecting the entire system. Additional valves allow you to fill the system with coolant and drain it. Also, in order to prevent freezing of water in houses with seasonal residence during cold periods, experts recommend removing the coolant completely from the system before temperatures drop.

The Proterm Skat boiler is connected to the electrical network via power line, summed up separately. The network cable is connected to the terminals, which are located in the lower corner of the case. All screws on the connectors must be carefully tightened. A boiler with a power of 9 kW can be connected to a single-phase network.

How to use the Proterm Skat boiler

The process of operating the Proterm Skat electric boiler does not cause any particular difficulties. After all, something like this heating equipment is equipped with systems for control and regulation. For the device to start working, you need to do just a few simple steps:

  1. Connect the unit to the power supply.
  2. Select the required temperature mode on the heating equipment control panel.
  3. Adjust the power of the unit.
  4. Make more precise adjustments temperature regime.
  5. If necessary, change the pressure level in the system.

After the completed manipulations, you must press the “Start” button. That's it, the Proterm Skat boiler is ready for use. During the first few days of operation, it is worth monitoring the operation of the unit and, if necessary, adjusting the temperature regime. This will identify some problems in the operation of the unit caused by the presence of air pockets in the system.

If you have a country house, but communications are not connected to it, then you can solve the issue expressed in the need for heating and water heating using boiler equipment. The main thing is to do right choice, because such an installation will take up space in the house and heating system central place. The choice should be made based on safety and reliability rules.

Modern heating equipment is offered in a huge range. You may prefer floor standing or wall model, with or without a chimney, non-volatile or powered. Modern manufacturers offer single-circuit and double-circuit heating equipment for sale. The former will be able to make the house more comfortable and cozy, while the latter will allow you to use hot water. Before making a choice, you need to read the reviews; Proterm boilers are no exception to this rule. They are offered in a wide range and may have different power and technical characteristics, you can read about this below.

Review of boilers from the manufacturer “Proterm”: “Bear 50 KLZ”

This equipment model costs RUB 143,914. It is a gas floor-standing boiler that can operate on mains fuel. The consumer will have the opportunity to provide a connection to liquefied gas. The equipment is double-circuit and is used for heating, as well as for hot water supply. The design has an open combustion chamber.

To remove combustion products, a fan must be connected. This Proterm Bear boiler has a 10-liter expansion tank. The heat exchanger is based on cast iron, which increases the reliability and service life of the boiler. The manufacturer made sure that the unit was protected from overheating of the coolant in the system. To do this, engineers equipped the model with a cooling circuit. Convenient start-up of the device is ensured by electric ignition.

Considering the model of heating equipment “Bear 50 KLZ”, we can mention that it has a power of 49 kW. The burner is modulating. The maximum power consumption is 50 kW. The gas temperature at minimum and maximum power is 115°C.

You may also be interested in how liquefied gas is consumed; the value is 3.8 kg per hour. Heating temperature is equivalent to 85°C. At 25°C coolant, productivity reaches 21 liters per minute. If the dimensions of the boiler room are limited, then you should take an interest in the design parameters, they are 1385x505x892 mm. The device weighs 210 kg. It belongs to the X4D protection class. Volume expansion tank- 10 l.

The coolant outlet temperature can reach up to 70 °C. The possible pressure of natural gas is 0.013 bar. Maximum flow natural gas 35.2 m 3 /h. If you plan to connect the equipment yourself, then you may need a chimney diameter of 180 mm. At one hundred percent thermal power efficiency equipment is 92%.

Reviews about the model

The above-described Proterm heating boiler, according to consumers, has many positive features, among them the following should be highlighted:

  • simple controls;
  • high efficiency;
  • independent regulation of thermal loads;
  • possibility of replacing middle cast iron sections.

As for ease of control, it is provided by an external panel with which you can adjust and control the parameters of the floor-standing model. Consumers emphasize that this equipment is used for systems with closed coolant circulation.

The device is controlled using a built-in microprocessor. Buyers, in their words, quite often choose this model for the reason that it provides the ability to independently adjust the thermal loads of the hot water supply and heating circuits. The unit is also good because it is resistant to complex hydraulic conditions.

User manual

After you familiarize yourself with the characteristics of the Proterm boiler that you have purchased or are just planning to purchase, it would not be a bad idea to ask what operating rules the manufacturer prescribes. Quite often, this allows you to extend the life of the equipment or prevent its breakdown. As for the model described above, it must be installed only in specially equipped rooms for this purpose.

The device is put into operation only after testing. It is important to follow safety regulations. They say that gas supply standards must be taken into account. You can set the water temperature in the boiler yourself. This also applies to heating temperature. In this case, the operator will have to use the MODE button.

To set the time intervals for heating water in the boiler, use a timer. Exploitation gas boiler“Proterm” is also convenient because on the panel you can see equipment messages about errors that occur during operation. For example, if you see an F1 code, it will indicate a loss of flame. But the designation F2 indicates that the boiler temperature sensor was faulty.

Review of the wall-mounted boiler brand "Gepard 23 MTV"

Another equipment option from the manufacturer Proterm is Gepard 23 MTV. You can purchase this model for RUB 42,088. The device was developed in 2015 and is used for heating as well as hot water supply.

The design provides for a closed combustion chamber, which makes it possible to use a coaxial chimney. The boiler has a primary heat exchanger made of copper. The burner is made of chromium-nickel steel. The heat exchanger in the device is plate-type, it is made of of stainless steel.

Specifications

The above-described Proterm Cheetah boiler has a power of 24.6 kW. Power consumption reaches 156 W. Buyers are often interested in the maximum consumption of natural gas, which is 2.9 m 3 /h. Temperature hot water the output can reach 65°C, while its minimum value is 35°C. The permissible natural gas pressure is 0.02 bar. The volume of the expansion tank is 5 liters.

The equipment belongs to the X4D protection class. The unit weighs 34 kg, this should be taken into account, because the Proterm wall-mounted boiler must be securely mounted on a vertical surface. Temperature flue gases is 110°C. Maximum fuel consumption when using liquefied gas is 2.1 kg per hour. The heating temperature can reach 83°C, while the minimum value is 35°C. If you plan to install the device in cramped conditions, then you should be especially interested in the dimensions of the unit; they are 740x310x410 mm.

Among the main advantages of the above-described equipment option, consumers highlight:

  • closed combustion chamber;
  • equipment coaxial system waste gases;
  • the ability to receive information about the operation of the boiler using a liquid crystal display;
  • automatic switching to hot water supply mode when opening a hot water tap.

If we compare this model with the previous one in the line, it was equipped by the manufacturer with a display. Its bright backlight allows the user to see data even in a bright room. The boiler is durable and reliable, which is ensured by a hydraulic block made of composite material. This feature improved the model compared to the previous generation, where the units were equipped with hydraulic units.

User manual

Instructions for the Proterm boiler are included. This is very convenient, because immediately after purchase you can familiarize yourself with it in order to avoid mistakes when using the device. If the boiler is not used for its intended purpose, this may pose a danger to human health and life. If you notice a strong smell of gas while operating the equipment, you should open the doors and windows wide, creating a draft. Do not use open flames or smoke, or turn on plugs, telephones or other intercoms in the building.

Do not store or use explosive or flammable substances such as paper, gasoline and paint in the same room as the boiler. Sufficient air supply must be provided for combustion. Protective devices do not need to be removed or bypassed during operation of the equipment. WITH protective systems It is not recommended to perform any manipulations.

Review of the Panther 35 kW boiler

This Proterm gas boiler has an affordable price of 63,398 rubles. The equipment is a two-circuit unit with closed camera combustion. The device includes a primary heat exchanger and plate heat exchanger hot water supply, which is made of stainless steel. The liquid crystal display is located on external panel, allowing the operator to see data even in a bright room. The risk of freezing is reduced, as is overheating thanks to additional elements security.

Model specifications

After reading the reviews about Proterm boilers, you can understand which model is better to choose. But it is also important to take into account the technical characteristics. For example, the Panther model has a power of 35 kW. Power consumption reaches 175 watts. The flue gas temperature at minimum power is 102.9°C. This traditional boiler provides a maximum power consumption of 38.4 kW.

__________________________________________________________________________

Installation, connection and startup of the Proterm Panther boiler

Mounted gas boiler Proterm Panther 25 KTV with forced exhaust of combustion products and model 25 KOV with natural exhaust, operating on natural gas or propane, are intended for heating and hot water supply of country houses, cottages, small garden buildings, communal buildings and other facilities that are equipped with a heating system with forced circulation of coolant and water supply.

Fig.1. Mounted gas boiler 25 KTV PANTHER

1 – closed (sealed) combustion chamber (turbochamber); 2 - burner atmospheric type; 3 - heat exchanger; 4 - circulation pump; 5 - air vent; 6 - heat exchanger of the DHW system; 7 - three-way valve drive; 8 - gas valve; 9 - ignition electrodes; 10 - control electrode; 11 - ignition unit; 12 - control panel; 13 - heating temperature sensor; 14 - emergency temperature sensor; 15 - traction sensor; 16 – fan; 17 – water pressure sensor

The boiler is designed to operate in a temperature range from +5 to 40 °C and relative humidity up to 85%.

The temperature of the external surfaces of the boiler unit (side and top cover) during boiler operation should not exceed the ambient air temperature by no more than 50°C.

When placing the boiler, it is not allowed to place objects near it:

From flame-resistant materials - at a distance of less than 100 mm from the surface;

Made from flammable materials, such as fibreboards, polyurethane, lightweight PVC, synthetic fibres, rubber, etc.

- at a distance of less than 200 mm from the surface.

It is necessary to leave a free space of at least 1 m in front of the boiler to carry out maintenance work.

In the Protherm Panther 25 KTV boiler, the removal of combustion products and the supply of air for combustion are carried out by a special coaxial pipeline or separate pipelines.

From standard parts you can create a coaxial chimney for almost all installation options. The length of the chimney, type and number of sections must be agreed with the service organization.

The chimney must be laid in such a way that condensate from combustion products can be removed. For this purpose, there are special sections that are built into the chimney route. The gas boiler Proterm Panther 25 KOV is designed to remove combustion products into the chimney with natural traction

. The boiler is connected to the chimney using a pipe with a diameter corresponding to the size of the chimney pipe. It is not allowed to install objects into the pipe that restrict the passage of combustion products (for example, different kinds

heat exchangers-heat recuperators, etc.).

Installation of gas boiler Proterm Panther
The Protherm Panther 25 KTV (KOV) boiler should be installed in closed heating systems with water as the coolant. The nominal diameter of the system pipes is selected based on the characteristics of the pump. The piping is designed according to the required capacity of a given system, and not the maximum

In this case, the coolant flow should be such that the temperature difference between the supply and return is no more than 20 °C. The minimum water flow in the system is 500 l/hour. The piping system must be designed to ensure that air is removed from it.

Air vents are located at the very high place in the system and on all radiators. The heating system is filled to a pressure of at least 1 bar.

The recommended pressure range in the system is 1.2 – 2 Bar. The boiler expansion tank is designed for a heating system capacity of 95 liters.. In larger systems, another expansion tank should be installed membrane type

Heating radiators

can be equipped with thermostatic valves.

If the unit is controlled by a room regulator, the thermostatic valves are not installed in the room where the room regulator is located. The system must be thoroughly cleaned before installation. DHW system Water pressure in DHW system should be in the range 1 - 6 Bar.

If the pressure exceeds 6 bar, a pressure reducing valve must be installed at the inlet. At high hardness

tap water

it is recommended to take appropriate measures to reduce it.

The connecting pipes have external threads. They must not be loaded with the weight of pipes from the heating system, hot water supply system or gas supply. It is necessary to strictly observe the installation dimensions of the connecting pipes (height, distance from the wall and between individual inlets and outlets).
At the bottom of the boiler there is a hydraulic group, which is equipped with a safety relief valve, a system filling (priming) valve and a drain valve. If the maximum pressure in the system (2.5 kgf/cm2) is exceeded, water may flow out of the safety relief valve or steam may escape.

It is recommended to connect the boiler to the heating system in such a way that during its repair it is possible to drain water only from the unit.

Check that the pressure in the DHW system is higher than the water pressure in the heating system.

Carefully open the filling valve in the hydraulic group and at the same time monitor the pressure increase on the boiler pressure gauge.

The tap opens by turning it counterclockwise, and turning it clockwise closes it.

When the required pressure is reached, the filling tap must be carefully closed and checked to see if the water pressure increases (the tap must be completely closed). If the DHW pressure in the water supply is the same or lower than the pressure in the heating system, water may leak into the water supply, which is unacceptable. This can be prevented by setting check valve

on the water supply pipe to the boiler. During repairs, unfavorable building layouts, etc., you can connect the boiler to the heating system, DHW system and gas supply with special.

flexible hoses When using flexible hoses, they must have a length of no more than 0.5 m, protected from mechanical stress and damage, and exposure to aggressive substances. At the end of their service life, the hoses must be replaced with new ones. To connect the boiler to a pipeline made of copper pipes

you can use a special connecting set of shaped copper pipes with fittings.

Tube sizes:
OB inlet and outlet – tube diameter 22 mm.
- DHW inlet and outlet – tube diameter 15 mm.
- Gas connection – tube diameter 22 mm.

- Safety valve connection – tube diameter 22 mm.

Gas connection Size 25 KTV (KOV) - ZP is designed to operate on natural gas with a nominal pressure in the distribution network of 1.8 kPa, and a calorific value of 35900 kJ/m3. Pipe diameter, fittings and gas meter

must be selected taking into account other gas appliances of the consumer. It is necessary to connect a pipe to the boiler with a minimum connecting diameter of 1/2“, but it is better with a nominal diameter of 3/4“. Size 25 KTV (KOV) - P is designed to work on liquefied gas (propane), s calorific value

from 12.3 to 13.0 kWh/kg.

Due to the fact that the operation of a boiler using cylinders is problematic, first of all, from the point of view of ensuring a sufficient number of them, as well as their further use, it is planned to simultaneously use a gas tank near the heated object and fill it with an authorized organization. Calculations required sizes supplying propane from a gas tank to a boiler unit or to other are part of the design and delivery of the gas tank. Using a gas pressure reducing valve, it is necessary to ensure a nominal gas pressure in front of the boiler of 3.0 kPa.

Air supply and combustion products exhaust

Is air supplied and combustion products removed through an external coaxial pipeline? 100 mm. Equivalent pipeline length (numerically equal to the sum linear meters straight pipe and the number of elbows 90°) should be no more than 9 m. For an equivalent pipeline length of more than 3 m, the throttle washer must be removed from the fan outlet.

Horizontal sections of the pipeline must be installed with a slope of at least 1.5% towards the flue gas outlet so that condensate flows out of the pipeline. In vertical sections, condensate drainage devices are used.

The pipeline outlet should be located:

At a height of at least 2 m from the foundation of the building in places visited by people and at least 0.4 m in places not visited by people;

At a distance of at least 0.5 m horizontally from windows that are constantly open ventilation grilles and doors;

Above the top border of windows, bars or doors;

In the area under awnings, balconies and roof edges.

Minimum distance between two adjacent pipeline outlets:

Horizontal – 1 m;
- vertically – 2 m.

The direction of the pipe exit should be oriented so that combustion products exit into open space.

The horizontal distance from the end of the pipeline outlet on one facade to the other, with opposite placement of outlets, should be:

2 m, if there are no windows or grilles on one facade;

1 m if both facades are without windows or bars;

4 m if both facades have windows or bars (or if there are adjacent exits on the same facade).

In the niche of the building facade, the distance between the axis of the pipeline outlet and the adjacent plane of the facade should be:

2 m if there are windows or bars on the facade;
- 0.5 m - if they are absent.

All distances are given from the outer boundary of the window (grid) or door to the axis of the pipeline. In the space under the canopy (balcony), the head of the pipe must be at a distance of at least the radius of the circle.

When pipelines exit vertically onto the roof, their heads must be placed at a distance of at least 0.4 m horizontally and at a height of at least 0.4 m from the roof surface, taking into account its shape.

The chimney outlet must not be located in an explosive area, internal parts buildings or structures, tunnels or underground passages, in closed spaces.

The hole in the wall for the passage of the coaxial pipeline is made with a certain gap (from 10 to 15 mm). Upon completion of installation, the gap is isolated non-flammable materials (polyurethane foam, gypsum, plaster).

Electrical connection of the gas boiler Proterm Panther

The Proterm Panther boiler must be connected to the electrical network through a plug socket with a grounding contact, which eliminates a “zero-phase” connection error. The distance from the boiler to the socket must be within the length of the boiler power cord (1 m).

The boiler must be connected to a protective conductor (grounding).

The grounding conductor must be accessible for inspection and resistance testing. For electrical connection

It is not allowed to use various tees, extensions, etc. The boiler is protected from overload and short circuit by fuses P1 – T80 mA/250V, P2 – T 1.6 A/250V, installed in the control panel. Before working with the electrical equipment of the boiler, it is necessary to disconnect the boiler from the network by disconnecting the electrical plug from the socket. To control the boiler from a room regulator, use a regulator with a potential-free output (other than the mains voltage, no other voltage is allowed to be supplied to the boiler). Connect the room regulator to the unit with a flexible two-core cable with a cross-section of 0.5 to 1.5 mm2. Exit the cable from the boiler through the plastic.

cable sleeve

The terminal block for connecting the room regulator and external sensor is located at the bottom, inside the boiler and is accessible after removing the outer cover and turning the control panel. Before connecting, the jumper must be removed from the terminal block. The minimum load of the regulator output contacts is 24 V / 0.1A. Sensor outside temperature should be connected with a two-core copper conductor with a cross section of 0.75 mm2. Wiring resistance should be no more than 10 ohms, maximum length

- 30 m.

The circuits for connecting the outside temperature sensor and the room regulator must not be laid together with the mains voltage circuits.

Work on putting the Protherm Panther boiler into operation:

Remove the screw securing the lid at the bottom of the boiler;

Tilt the cover down (toward you) and lift it off the pins at the top of the camera.

Make sure the gas supply is turned off.

Loosen the cap on the automatic air separator located on the pump.

Connect the boiler to the electrical network.

Press the Bar/Mode button. The display will show 0.0 (pressure value) and the LED will light up.

The pressure value is displayed for about 25 seconds. After this, the display returns to its original position. The pressure value can be displayed again by pressing the Bar/Mode button.

Fill the system with water, the pressure should be between 1.2 and 2 bar.

Gently release the air from all heating devices(the flow of water should be continuous, without air bubbles).

Leave the cap on the air separator loose while the boiler is operating.

Open the DHW taps to remove air from the DHW circuit;

Make sure that the pressure shown on the display is in the range of 1.2 - 2 Bar, top up if necessary.

Starting the Proterm Panther boiler

Before starting the boiler, check:

The main gas supply valve is open,
- gas tap open at the entrance,
- closing valves (water, heating) at the outlet are open,
- the unit is connected to the electrical network.

To start the Protherm Panther boiler, do the following:

Switch the power switch to position “I”;

Set the extract air temperature to 85 °C and switch off the equithermal control (E-).

Check the condition of the room regulator (it must be closed);

Smoothly raise the temperature in the heating system to maximum (all radiators should have open valves). The air in the water of the heating system is gradually removed through an automatic air separator. There should be no air at the highest point of the system and in the radiators;

Make up the system to a pressure of 1.2 Bar;

Turn on the boiler again and heat the system to maximum temperature;

Turn off the boiler, remove air if necessary and refill the system with water;

Make sure that after the heating system has cooled down, the pressure gauge shows at least 1.2 Bar;

If the pressure in the heating system in the heated state is higher by. 0.5 bar than when cold, check the setting of the expansion tank relative to the system.

Protective functions of the Proterm Panther boiler

The boiler is equipped with a frost protection function. When the temperature drops below 10 °C, the pump will automatically turn on. When the temperature drops below 8 °C, the device will ignite and operate until the temperature rises by 25 °C. In case of freezing (exhaust temperature below 3 °C), the boiler start-up is blocked.

The pump switches on automatically for a short time if it has not been switched on for 24 hours. This ensures protection against blocking due to deposits during prolonged shutdown. The pump operates continuously when the temperature rises above 85°C (overheat protection).

When the pressure drops, the LED flashes; when the pressure drops further, the unit goes out (protection against water loss - alarm F0). When the pressure increases, operation automatically resumes.

The protective functions are only activated when the boiler is connected to the mains voltage (the electrical cord is in the socket and the mains switch is in the on position (I).

If the boiler has been disconnected from the mains voltage for a long time (a month or more), it is recommended to start it periodically (at least once a month). The boiler is equipped with a safety valve. When discharging heating water from the valve, turn off the boiler and disconnect it from the mains voltage.

Adjusting the Protherm Panther boiler

When the boiler operates without a room regulator, it maintains the temperature set on the display.

Adjustment operations:

– select the equithermal regulation mode – select the heating curve and set the E- symbol;

– select the equithermal regulation mode – in the parallel movement option put the symbol P-;

– select the Exhaust temperature mode and configure it;

– the room regulator must be turned off, and a jumper must be installed between the terminals to connect it.

When the Proterm Panther boiler operates with a room regulator, it maintains the temperature set on the display. In this case, the unit turns off according to commands room thermostat installed inside the control room. There should be no thermostatic valve on the radiator in this room.

During installation, the jumper is removed from the boiler terminals and the room thermostat is connected. When operating in equithermal mode, the temperature changes depending on the change in outside air temperature.

An outside air temperature sensor must be connected to the boiler. The sensor is installed on the cold wall
building (north or north-west) at a height of about 2.5 - 3 m. The sensor should not be located in the area of ​​​​ventilation emissions from windows or other ventilation devices

and exposed to direct sunlight.

Inlet gas pressure control:

Turn off the boiler.

Connect the appropriate pressure meter;

Carry out the launch;

Check the gas inlet pressure, if it is below normal, check the tightness of the gas pipeline;

Turn off the unit and disconnect the pressure meter, carefully tighten the screw on the measuring fitting and check its tightness.

Electric boilers are in demand among owners of country houses, residential cottages and other non-gasified buildings. They are characterized by good functionality and allow you to heat any buildings that are not connected to gas mains. Their typical representative is the Proterm electric boiler - this is a device from famous manufacturer, different high quality assembly and decent characteristics.

We decided to devote this review to Protherm electric boilers. In it we will tell you:

Equipment from such a renowned manufacturer really deserves special mention, so we will tell you everything we know about Proterm boilers.

Features of Proterm electric boilers

By installing such an electrical unit in your household, you are doing great choice. Instead of buying equipment from dubious brands, it is better to overpay a little and take a really worthwhile item from a well-known manufacturer - the performance of the entire system depends on the quality of the boiler used. Moreover, the Protherm company has extensive experience in the production of electric heating equipment.

There is only one the lineup- Skat.

Heating homes not connected to gas mains is always a big problem. Electric boilers existing on the market are either high cost or cannot boast of sufficient functionality. In this case, you always pay attention to small-sized and neat gas models, operating automatically and not cluttering up the space. The Protherm company is ready to offer owners of country houses similar solutions, but powered by the electrical network.

Protherm electric boilers are a unique solution that is economical. They are installed in both residential and non-residential buildings, regularly generating heat. Presented as a single model range called Skat - customers can choose from samples with thermal power from 6 to 28 kW. Thanks to this, they can heat rooms up to 280 square meters. m.

What are they good for?

  • Simple single-circuit design - if you like simple and reliable equipment, you will definitely like the products of the specified brand;
  • Wide power range – it is possible to choose a device that is suitable in terms of power and price;
  • High efficiency – efficiency, according to the manufacturer, is 99.5%. This means that almost all of the expended electricity is converted into heat, without significant losses;
  • Absolutely silent operation - even if the equipment is in the bedroom, it will not interfere with a good night's sleep;
  • Precise temperature control – create a comfortable and cozy atmosphere in your home;
  • Availability of universal models - they can operate from single-phase and three-phase networks with a voltage of 220 or 380 V;
  • Easy installation - you can handle the installation yourself, without the help of specialists.

Prices range from 37,900 to 47,000 rubles - this is the official price from the manufacturer as of April 2016. In some other stores it may differ up or down (usually more). But nothing will stop you from buying a Proterm electric boiler in the official online store - this is the most economical and reliable option.

The cost of the equipment may seem high, but Protherm always stands behind the quality of its products.

Technical characteristics and appearance

The Proterm electric boiler will fit into any interior thanks to its small sizes and wall placement.

As expected good equipment from famous brand, Proterm electric boilers are housed in neat, compact housings. Thereby they can fit into any interior, even the most sophisticated ones. Case dimensions – height 740 mm, depth – 310 mm, width – 410 mm (dimensions are identical for the entire Skat model range). Inside we will find everything you need for the heating system to work:

  • Circulation pump;
  • Automatic air vent;
  • Expansion tank 7 liters.

There is no need to worry about installing the piping - just connect the pipes and radiators, fill the system with coolant, after which you can start testing.

Models with a power of 6 kW and 9 kW can operate from both single-phase and three-phase networks. More powerful ones are three-phase. The equipment is not afraid of power surges and does not cause overloads on the network - a stepwise increase in power is provided here. The maximum current in the circuit when the heating elements are operating is up to 50 A. The maximum coolant pressure in the system is 3 atm, the temperature is up to +85 degrees.

When connecting Protherm electric heating boilers to the electrical network, you must ensure that the cross-section of the wires corresponds to the power consumption.

Layout of inlets for Proterm electric boilers, as well as their dimensions.

Protherm electric boilers are equipped with convenient control panels. They contain LED indicators and liquid crystal displays. Self-diagnosis systems are provided - error codes are displayed on built-in screens. For creating comfortable atmosphere thermostats are used. Safety systems include an overheating sensor, frost protection, a pressure sensor, a safety valve and an anti-blocking system for the circulation pump.

An interesting functionality is the ability to connect external storage boilers, which are purchased separately.

Popular models

The electric boiler Protherm Skat 9 KR 13 is the most popular. Used to heat rooms up to 90 square meters. m.

As we have already said, electric boilers from Protherm are represented by the only Skat line. Therefore, all equipment has similar characteristics, differing electrical power and current consumption - all other data is identical, down to dimensions and weight. As for the most popular models, they are designs with a power of 9 kW, 12 kW and 21 kW.

In addition, the Skat model range includes models with a power of 6 kW, 14 kW, 18 kW, 24 kW and 28 kW - the maximum heating area depends on the power (calculations must take into account heat loss and the possibility of connecting a boiler).

Instructions for use

When installing and configuring the device, you must follow safety regulations and use protective equipment. Boilers are installed in a dry place, away from flammable structures, emergency exits, air conditioners and other electrical appliances. Installation in places where water may enter the equipment is not allowed.. Also, operation in freezing areas is not allowed.

Mount the equipment on solid walls, taking into account the weight. Heating pipes must fit smoothly and without distortions. Connection to the electrical network is carried out using wires of suitable cross-section, directly to electrical panel, through additional RCD machines. For impact protection electric shock the equipment must be grounded. You also need to make sure that the supply voltage complies with the established standards. External components and modules are connected in accordance with the instructions.

Calculation table required section wires and fuse ratings depending on power

Ideally, the installation should be carried out by certified specialists, but if you follow the instructions and follow the safety rules, nothing bad will happen.

During equipment operation, it is necessary to monitor the temperature in the system and respond to possible mistakes. If the equipment is working properly, users can only set the desired temperature. The temperature of the heating circuit and the temperature in the external storage boiler (if equipped) are selected using the buttons on the control panel - parameters and errors are monitored using the LCD display.



 
Articles By topic:
Why do the testicles itch and what to do to get rid of the discomfort?
Many men are interested in why their balls begin to itch and how to eliminate this cause. Some believe that this is due to uncomfortable underwear, while others think that it is due to irregular hygiene. One way or another, this problem needs to be solved.
Why do eggs itch?
Minced meat for beef and pork cutlets: recipe with photos
Until recently, I prepared cutlets only from homemade minced meat.  But just the other day I tried to cook them from a piece of beef tenderloin, and to be honest, I really liked them and my whole family liked them.  In order to get cutlets
Schemes for launching spacecraft Orbits of artificial Earth satellites
1 2 3 Ptuf 53 · 10-09-2014 The union is certainly good.  but the cost of removing 1 kg of cargo is still prohibitive.  Previously, we discussed methods of delivering people into orbit, but I would like to discuss alternative methods of delivering cargo to rockets (agree with
Grilled fish is the most delicious and aromatic dish